Anolis ArcPad 48 Integral Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Lumières des projecteurs Anolis ArcPad 48 Integral. P R O D U C T G U I D E 2 0 0 9 / 2 0 1 0 Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 68
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
ANOLIS is an architectural division of ROBE
HQ & Factory: ROBE lighting s. r. o., Hážovice 2090, 756 61 Rožnov p. Radhoštěm, Czech Republic, Tel.: +420 571 751 500, Fax: +420 571 626 337, E-mail: [email protected]
UK: ROBE UK Ltd., Northampton, UK, Tel.: 01604 741000, E-mail: [email protected], South-East Asia: ROBE S.E.A., Singapore, Tel.: +65-8118 6665, E-mail: [email protected]
America: ROBE Lighting Inc., Sunrise, FL, USA, Tel.: +1 954 615 9100, E-mail: [email protected]
September 2009
www.anolis.eu
PRODUCT GUIDE 2009/2010
Vue de la page 0
1 2 3 4 5 6 ... 67 68

Résumé du contenu

Page 1 - PRODUCT GUIDE 2009/2010

ANOLIS is an architectural division of ROBEHQ & Factory: ROBE lighting s. r. o., Hážovice 2090, 756 61 Rožnov p. Radhoštěm, Czech Republic, Tel.:

Page 2

Private House, Sovereign Island, Gold Coast, Australia

Page 3

11DIMENSIONS:The Anolis ArcSource 12 combines state of the art lighting technology within an industry standard AR1-11 size fi tting

Page 4 - ANOLIS ADVANTAGES

Woodchester Mansion, Stroud, The United Kingdom

Page 5 - ANOLIS LED GREEN STATEMENT

13 ArcSource 3/K2TM Max. input current: 700mAMaximum Power Consumption: 7.6 WattsCompatible power supplies: ArcPower 36/K2, ArcPower 72/K2Compa

Page 6

Ice Space, London, The United Kingdom

Page 7

15The Anolis ArcSource Inground range brings the high standards of the ArcSource range to the world of exterior lighting. Industry standard I

Page 8

Somerset House, London, The United Kingdom (photo credits: Somerset House)

Page 9

17 ArcSource Inground 12TM Max. input current: 350 mAMaximum Power Consumption: 13.6 WattsCompatible Power Supplies: ArcPower 36, 72, 144, 36

Page 10

Fountain, Lidcombe, Sydney, Australia

Page 11 - (AR1-11)

19Manufactured from 316 stainless steel and with an IP rating of 68 the ArcSource Outdoor 3, 6, 7 make the perfect companion for the ArcSour

Page 13 - ArcSource

St Stephen´s Church, Bath, The United Kingdom

Page 14

21 ArcSource Outdoor 12TM ArcSource Outdoor 36TM Max. input current: 350 mA 350 mAMaximum Power Consumption: 13.6 Watts 40.8 WattsCompatibl

Page 15

Mica Club, Rome, Italia

Page 16

23ArcSource ArcSource Wall 3TM ArcSource Twin Wall 3TM Max. input current: 350 mA 350 mAMaximum Power Consumption: 4.2 Watts 8.4 WattsComp

Page 17

Tabu Bar, Budapest, Hungary (photo credits: Collossal Sound)

Page 18

25ArcLink ArcLink 3TM ArcLink Optic 3TM Max. input current: 350 mA 350 mAMaximum Power Consumption: 3.4 Watts 3.4 WattsCompatible Power Su

Page 19

Grand Ballroom of the Merrimu Reception Centre, Melbourne, Australia

Page 20

27Other dimensional and colour variants on request.DIMENSIONS:ArcLineThe Anolis ArcLine combines state of the art lighting technology with

Page 21

Private House, Sovereign Island, Gold Coast, Australia

Page 22 - Mica Club, Rome, Italia

29Other dimensional and colour variants on request.DIMENSIONS:ArcLineThe Anolis ArcLine Optic range combines state of the art lighting tech

Page 23

ANOLIS was established to design and manufacture top-end LED lighting products.Since its conception, ANOLIS has gone from strength to strength, produc

Page 24

Industrie & Handels-Kammer Building, Brauchenschweig, Germany

Page 25 - DIMENSIONS:

31 ArcLine Optic 12 SmartWhiteTM ArcLine Optic 24 SmartWhiteTM ArcLine Optic 36 SmartWhiteTM Max. input current: 350 mA 350 mA 350 mAMaxi

Page 26

Casino at Leicester Square, London, The United Kingdom

Page 27

33ArcLine Outdoor Optic 18, 24, 36 ArcLine Double Outdoor Optic 36, 48, 72 ArcLine Outdoor Optic 18TM ArcLine Outdoor Optic 24TM ArcLine Outdo

Page 28

Gold Coast Convention & Exhibition Centre – Gold Coast, Queensland.

Page 29

35ArcLine Outdoor Optic 18, 24, 36/K2 ArcLine Double Outdoor Optic 36, 48, 72/K2 ArcLine Outdoor Optic 18/K2TM ArcLine Outdoor Optic 24/K2TM

Page 30

Styx Disco, Malta

Page 31

37 ArcPAR 3TM ArcPAR 12TM Max. input current: 350 mA 350 mAMaximum Power Consumption: 4.2 Watts 13.6 WattsCompatible Power Supplies: Arc

Page 32

College Michel-de-Swaen, Dunkerque, France

Page 33

39ArcPad 48, ArcPad 48 IntegralDIMENSIONS:ArcPadThe ArcPad 48 and ArcPad 48 Integral are designed for the generation of rich, saturated colours and co

Page 34

4ANOLIS ADVANTAGESAs the global LED lighting market is currently growing at a phenomenal rate there is a huge choice for today’s li

Page 35

Dunkerque Littoral Pole de Valorisation des Dechets, France

Page 36 - Styx Disco, Malta

41 ArcPad XtremeTM Light source: 188 RGBW LEDsLED device: Luxeon K2Number of LED modules: 2Typical Lumen Maintenance: 70% @ 60.000 hoursAvai

Page 37

Izamal Convent, Mexico

Page 38

43 ArcSource 96 IntegralTM Light source: 96 RGBW LEDsLED device: Luxeon RebelAvailable optical systems: Standard 25°, optional 12°, 45° and 45

Page 39

Styx Disco, Malta

Page 40

45DIMENSIONS: ArcWash 236TM Input Voltage: 100-240 V AC, 50/60 HzMaximum Power Consumption: 180 VALight source: 36 x K2 Luxeon LED´s (12 Red

Page 41

Ice Space, London, The United Kingdom

Page 42 - Izamal Convent, Mexico

47 ArcPower 9TMInput Voltage: 110-240 V AC, 50/60 HzDesigned for: Single colour variants of ArcLink/Optic 3, 4; ArcSource 3, 6, 7; ArcSource O

Page 43

Mentone Hotel, Melbourne, Australia

Page 44

49 ArcPower 36TM ArcPower 72TMInput Voltage: 100-240 V AC, 50/60 Hz 100-240 V AC, 50/60 HzMaximum Power Consumption: 60 W 120 WNumber of LED

Page 45

5ANOLIS LED GREEN STATEMENTGovernments and Lighting professionals worldwide all agree that the recent advances in LED technology hold tremendous poten

Page 46

Private House, Sovereign Island, Gold Coast, Australia

Page 47 - ArcPower

51 ArcPower 36 SmartWhiteTM ArcPower 72 SmartWhiteTM ArcPower 144 SmartWhiteTMInput Voltage: 100-240 V AC, 50/60 Hz 100-240 V AC, 50/60 Hz

Page 48

Gilgermesh Restaurant, London, The United Kingdom

Page 49

53 ArcPower 36/K2TM ArcPower 72/K2TMInput Voltage: 100-240 V AC, 50/60 Hz 100-240 V AC, 50/60 HzMaximum Power Consumption: 120 W 240 WNum

Page 50

Amara Hotel, Sentosa, Singapore

Page 51

55 ArcPower 36/K2 SmartWhiteTM ArcPower 72/K2 SmartWhiteTMInput Voltage: 100-240 V AC, 50/60 Hz 100-240 V AC, 50/60 HzMaximum Power Consumpti

Page 52

Paddington Tavern, Brisbane, Australia

Page 53

57 ArcPower 16x6TMInput Voltage: 100-240 V AC, 50/60 HzMaximum Power Consumption: 170 WNumber of LED output zones: 16Max.Output current: 35

Page 54

Leeds Academy, Leeds, The United Kingdom

Page 55

59ArcPower 48DIMENSIONS:ArcPowerThe ArcPower has been designed and manufactured to the same high standards as the ArcPower 36 to bring to life the phe

Page 56

Ula Office, Queensland, Australia (photo credits: Ula)

Page 57

Krys Optical, Wattrelos, France

Page 58

61 ArcPower 384 Rack-MountTM Power supply: Electronic auto-rangingInput Voltage: 100-250 V AC, 50/60 HzMaximum Power Consumption: 650 WNumber

Page 59

Gilgermesh Restaurant, London, The United Kingdom

Page 60

63 ArcControl 1024TM DMX Channels: 2 complete universes of 512 channels eachDMX Standard: DMX 1990 ADMX refresh rate: Confi gurable, 36 Hz Max

Page 61

Gilgermesh Restaurant, London, The United Kingdom

Page 62

65 ArcSplitter 4TM ArcSplitter 2x12TMNumber of LED outputs: 4 2x12LED in/out: RJ 45 sockets RJ 45 socketsConstruction: No extra PSU

Page 63 - ArcControl

66CONTENT:  ArcSource 1 ...

Page 64

67NOTES:

Page 65 - ArcSplitter 4, 2x12

ANOLIS is an architectural division of ROBEHQ & Factory: ROBE lighting s. r. o., Hážovice 2090, 756 61 Rožnov p. Radhoštěm, Czech Republic, Tel.:

Page 66 - CONTENT:

7ArcSource The Anolis ArcSource 1 is a single colour high powered LED fi xture utilising the latest Luxeon high output LED’s. Available in 4 optical f

Page 67

Consortium Club - Queensland, Australia (photo credits: ULA)

Page 68

9The Anolis ArcSource 3 RGB, 6 RGB, 7 RGBW combines state of the art lighting technology with industry standard MR16 fi ttings to create tr